AFPM type fire equipment power monitoring system
时间: 2018-10-19 14:36 浏览次数: 来源:6165金沙总站

  1 Overview

  The AFPM series fire equipment power monitoring system can monitor the power of the fire equipment in real time. By detecting the voltage, current, switch status and other related equipment power information of the fire equipment, it is judged whether the power equipment has open circuit, short circuit, over voltage, and ow Monitoring system for fault information such as pressure, phase loss, phase error and overcurrent (overload) and alarming and recording. The system is reliable, real-time and features digital, intelligent, networked, automated and continuous monitoring. Real-time reflection of the status of the power of the monitored equipment, and centralized display, which can effectively avoid the critical situation that the fire-fighting equipment can not work normally due to power failure during the fire, and maximize the reliability of the fire-fighting linkage system.

  Applicable to intelligent buildings, high-rise apartments, hotels, restaurants, commercial buildings, industrial and mining enterprises, national key fire protection units, petrochemicals, culture, education, health, finance, telecommunications, etc., in line with GB 28184-2011 "Fire Equipment Power Monitoring System" and GB 25506- 2010 Standard for General Technical Requirements for Fire Control Rooms.

  2 Applicable environment

  Working temperature: -10 ° C ~ +55 ° C

  Storage temperature: -20 ° C ~ +70 ° C

  Relative humidity: ≤95% no condensation

  Altitude: ≤2500m

  Pollution degree: Class III, installation category: Level III

  3 system function

  3.1 Monitoring alarm

  Monitored device power loop switch status

  Working status of the monitored equipment power supply (voltage, current and alarm status information)

  Alarm response time: ≤30s

  Alarm sound signal: can be manually eliminated, can be started again when there is an alarm signal input again

  Alarm light signal: red LED indicator is always on

  3.2 Fault alarm

  The connection between the monitor and the module (voltage/current signal sensor) is open and shorted

  Monitor mains undervoltage (≤80% mains voltage) or overvoltage (≥110% mains voltage)

  The connection between the monitor and its separate power supply is open and shorted.

  When the above fault occurs in the monitor, it can emit an acousto-optic fault alarm signal that is clearly different from the monitoring alarm signal.

  Fault alarm response time: ≤100s

  Fault alarm sound signal: manual elimination, can be started again when there is alarm signal input again

  Fault alarm light signal: yellow LED indicator is always on

  The normal operation of the non-faulty loop is not affected during the fault

  3.3 Control output

  Remote remote operation of alarm relays for individual or all monitored equipment

  Monitor alarm control output: normally open passive contact, capacity: AC250V 3A or DC30V 3A

  Monitor control output: normally open passive contact, capacity: AC250V 3A or DC30V 3A

  3.4 Self-test

  Connection check: open and short circuit of communication line and split power line

  Equipment self-test: manual inspection or system self-test

  Self-test time: ≤60s

  3.5 Alarm record

  Record 10000 related fault alarm information

  Alarm type: fault type, time of occurrence, fault description

  Alarm event query:

  Alarm record printing: (optional)

  3.6 Operational classification

  Daily duty class: You can enter the software interface to view real-time monitoring, eliminate alarm sounds and query alarm records.

  Monitoring operation level: operations other than information maintenance for the system itself

  System management level: any functional module of the operating system

  4 AFPM100 monitoring detector

  4.1 Working power supply

  Main power supply: AC220V 50Hz (allows 85%~110% range change)

  Backup power supply: When the main power supply is low voltage or power failure, maintain the monitoring equipment working time ≥8h

  The monitor provides DC24V power to the connected modules (voltage/current signal sensors)

  4.2 Work system and transmission method

  24-hour working system, Modbus-RTU communication protocol, RS485 half-duplex bus mode, transmission distance of 1km (can extend communication transmission distance through repeater).

  4.3 Main parameters and components

  The FPM100 fire equipment power status monitor is a wall-mounted installation. Its main functions and components are as follows:

  Monitoring capacity: ≤128 points

  Display mode: 320*240 dot matrix LCD

  Input and output module: built-in remote intelligent I / O module

  Sound and light alarm module: built-in speaker, buzzer, LED indicator

  Backup power: DC24V, 10Ah (optional with larger capacity battery)

  5 power monitoring module (voltage / current signal sensor)


  5.1 AFPM1-AV, AFPM1-AVI, AFPM1-DV, AFPM1-DVI, AFPM1-2AV single-phase power monitoring module

  5.1.1 Features

  Real-time monitoring of one-way AC voltage/current, one DC voltage/current, or two single-phase AC voltages; (see module selection for details)

  With overvoltage, undervoltage, overcurrent (only with current detection products) alarm; (see module selection for details)

  Provide one or two channels (only monitor two single-phase AC voltage products) switch input function, can monitor the switch status; (see module selection for details)

  Provide one relay output, which can be connected to the alarm control loop;

  With event storage function, the alarm can record the time, type and parameter of the alarm occurrence, and can analyze the scene according to the alarm record to provide a basis for eliminating the fault;

  Using fieldbus communication technology, the host computer management software can monitor the operation of the site at all times and timely discover the alarm information. The standard MODBUS protocol can be connected to various standard systems via the RS485 interface;

  High integration, network, high degree of intelligence, reasonable motion characteristics.

  5.1.2 Technical parameters



  5.1.3 Outline and installation dimensions



  5.1.4 Terminals



  5.2AFPM3-AV, AFPM3-AVI, AFPM3-2AV three-phase power monitoring module

  5.2.1 Features

  Real-time monitoring of one-way three-phase AC voltage/current, or two-way three-phase voltage; (see module selection for details)

  With overvoltage, undervoltage, phase loss, phase error, overcurrent (only for current detection products) alarm; (see module selection for details)

  Provide one or two channels (only monitor two-way three-phase AC voltage products) switch input function, can monitor the switch status; (see module selection for details)

  Provide one relay output, which can be connected to the alarm control loop;

  With event storage function, the alarm can record the time, type and parameter of the alarm occurrence, and can analyze the scene according to the alarm record to provide a basis for eliminating the fault;

  Using fieldbus communication technology, the host computer management software can monitor the operation of the site at all times and timely discover the alarm information. The standard MODBUS protocol can be connected to various standard systems via the RS485 interface;

  High integration, network, high degree of intelligence, reasonable action characteristics;

  5.2.2 Technical parameters



  5.2.3 Outline and installation dimensions



  5.2.4 Terminal Blocks



  5.3 AFPM5-2/2, AFPM-6/1 Switch Module

  5.3.1 Features

  Provide two or six digital input functions to monitor the switch status; (see module selection for details)

  Provide one or two relay outputs, which can be connected to the alarm control loop; (see module selection for details)

  With event storage function, the alarm can record the time, type and parameter of the alarm occurrence, and can analyze the scene according to the alarm record to provide a basis for eliminating the fault;

  Using fieldbus communication technology, the host computer management software can monitor the operation of the site at all times and timely discover the alarm information. The standard Modbus protocol can be connected to various standard systems via the RS485 interface;

  High integration, network, high degree of intelligence, reasonable action characteristics;

  5.3.2 Technical parameters



  5.3.3 Outline and installation dimensions



  5.3.4 Terminal Blocks


上一篇:AFRD fire door monitoring system
下一篇:RCM residual current type electric fire monitoring device

版权所有金沙网址 沪ICP备18001305号-7

咨询热线:021-69157502  手机:187-0211-2013

传真:021-69158302  地址:上海市嘉定区育绿路253号

主要销售地区:上海,北京,广东,山东

公司自成立以来一直专注于用户端智能电力仪表的研发应用、生产和销售,致力于为用户提供电能质量治理、电能分项计量、
电气火灾监控系统包括多用户计量箱、电气火灾监控、智能照明控制、能耗监测系统、预付费电力系统等   网站地图-XML